Specification List
-
is read with S0003 Specifications::Site::Traffic Light Controller::IO::Input
-
forcing is read with S0029 Specifications::Site::Traffic Light Controller::IO::Input
-
forcing is set with M0019 Specifications::Site::Traffic Light Controller::IO::Input
-
is activated with M0006 Specifications::Site::Traffic Light Controller::IO::Input
-
series is activated with M0013 Specifications::Site::Traffic Light Controller::IO::Input
-
sensitivity is set with M0021 Specifications::Site::Traffic Light Controller::IO::Input
-
is read with S0004 Specifications::Site::Traffic Light Controller::IO::Output
-
forcing is read with S0030 Specifications::Site::Traffic Light Controller::IO::Output
-
forcing is set with M0020 Specifications::Site::Traffic Light Controller::IO::Output
-
Alarm A0302 is raised when input is activated Specifications::Site::Traffic Light Controller::Alarm
-
A0302 can be acknowledged Specifications::Site::Traffic Light Controller::Alarm
-
A0302 can be suspended and resumed Specifications::Site::Traffic Light Controller::Alarm
-
can be read with S0096 Specifications::Site::Traffic Light Controller::Clock
-
can be set with M0104 Specifications::Site::Traffic Light Controller::Clock
-
is used for S0096 status response Specifications::Site::Traffic Light Controller::Clock
-
is used for S0096 response timestamp Specifications::Site::Traffic Light Controller::Clock
-
is used for aggregated status timestamp Specifications::Site::Traffic Light Controller::Clock
-
is used for M0001 response timestamp Specifications::Site::Traffic Light Controller::Clock
-
is used for M0104 response timestamp Specifications::Site::Traffic Light Controller::Clock
-
is used for alarm timestamp Specifications::Site::Traffic Light Controller::Clock
-
is used for watchdog timestamp Specifications::Site::Traffic Light Controller::Clock
-
control mode is read with S0020 Specifications::Site::Traffic Light Controller::Operational
-
startup status is read with S0005 Specifications::Site::Traffic Light Controller::Operational
-
switched on is read with S0007 Specifications::Site::Traffic Light Controller::Operational
-
manual control is read with S0008 Specifications::Site::Traffic Light Controller::Operational
-
fixed time control is read with S0009 Specifications::Site::Traffic Light Controller::Operational
-
fixed time control can be activated with M0007 Specifications::Site::Traffic Light Controller::Operational
-
isolated control is read with S0010 Specifications::Site::Traffic Light Controller::Operational
-
coordinated control is read with S0032 Specifications::Site::Traffic Light Controller::Operational
-
yellow flash can be read with S0011 Specifications::Site::Traffic Light Controller::Operational
-
yellow flash can be activated with M0001 Specifications::Site::Traffic Light Controller::Operational
-
yellow flash affects all signal groups Specifications::Site::Traffic Light Controller::Operational
-
all red can be read with S0012 Specifications::Site::Traffic Light Controller::Operational
-
police key can be read with S0013 Specifications::Site::Traffic Light Controller::Operational
-
dark mode can be activated with M0001 Specifications::Site::Traffic Light Controller::Operational
-
yellow flash be used with a timeout of one minute Specifications::Site::Traffic Light Controller::Operational
-
operator logged in/out of OP-panel is read with S0091 Specifications::Site::Traffic Light Controller::System
-
operator logged in/out of web-interface is read with S0092 Specifications::Site::Traffic Light Controller::System
-
version is read with S0095 Specifications::Site::Traffic Light Controller::System
-
security code is set with M0103 Specifications::Site::Traffic Light Controller::System
-
security code is rejected when incorrect Specifications::Site::Traffic Light Controller::System
-
is correct for rsmp version 3.1.1 Specifications::Site::Core::Connection Sequence
-
is correct for rsmp version 3.1.2 Specifications::Site::Core::Connection Sequence
-
is correct for rsmp version 3.1.3 Specifications::Site::Core::Connection Sequence
-
is correct for rsmp version 3.1.4 Specifications::Site::Core::Connection Sequence
-
is correct for rsmp version 3.1.5 Specifications::Site::Core::Connection Sequence
-
is correct for rsmp version 3.2 Specifications::Site::Core::Connection Sequence
-
is correct for rsmp version 3.2.1 Specifications::Site::Core::Connection Sequence
-
is correct for rsmp version 3.2.2 Specifications::Site::Core::Connection Sequence
-
can be turned on and off for S0001 Specifications::Site::Traffic Light Controller::Subscription
-
is closed if watchdogs are not acknowledged Specifications::Site::Core::Connection
-
is not closed if watchdogs are not received Specifications::Site::Core::Connection
-
currently active is read with S0014 Specifications::Site::Traffic Light Controller::Signal Plan
-
currently active is set with M0002 Specifications::Site::Traffic Light Controller::Signal Plan
-
list size is read with S0018 Specifications::Site::Traffic Light Controller::Signal Plan
-
list is read with S0022 Specifications::Site::Traffic Light Controller::Signal Plan
-
week table is read with S0026 Specifications::Site::Traffic Light Controller::Signal Plan
-
week table is set with M0016 Specifications::Site::Traffic Light Controller::Signal Plan
-
day table is read with S0027 Specifications::Site::Traffic Light Controller::Signal Plan
-
day table is set with M0017 Specifications::Site::Traffic Light Controller::Signal Plan
-
version is read with S0097 Specifications::Site::Traffic Light Controller::Signal Plan
-
M0018 set cycle time Specifications::Site::Traffic Light Controller::Signal Plan
-
dynamic bands are read with S0023 Specifications::Site::Traffic Light Controller::Signal Plan
-
dynamic bands are set with M0014 Specifications::Site::Traffic Light Controller::Signal Plan
-
dynamic bands values can be changed and read back Specifications::Site::Traffic Light Controller::Signal Plan
-
timeout for dynamic bands is set with M0023 Specifications::Site::Traffic Light Controller::Signal Plan
-
offset is read with S0024 Specifications::Site::Traffic Light Controller::Signal Plan
-
offset is set with M0015 Specifications::Site::Traffic Light Controller::Signal Plan
-
cycle time is read with S0028 Specifications::Site::Traffic Light Controller::Signal Plan
-
cycle time is set with M0018 Specifications::Site::Traffic Light Controller::Signal Plan
-
number of vehicles for a single detector is read with S0201 Specifications::Site::Traffic Light Controller::Traffic Data
-
number of vehicles for all detectors is read with S0205 Specifications::Site::Traffic Light Controller::Traffic Data
-
vehicle speed for a single detector is read with S0202 Specifications::Site::Traffic Light Controller::Traffic Data
-
vehicle speed for all detectors is read with S0206 Specifications::Site::Traffic Light Controller::Traffic Data
-
occupancy for a single detector is read with S0203 Specifications::Site::Traffic Light Controller::Traffic Data
-
occupancy for all detectors is read with S0207 Specifications::Site::Traffic Light Controller::Traffic Data
-
classification for a single detector is read with S0204 Specifications::Site::Traffic Light Controller::Traffic Data
-
classification for all detectors is read with S0208 Specifications::Site::Traffic Light Controller::Traffic Data
-
is ordered to green with M0010 Specifications::Site::Traffic Light Controller::Signal Group
-
is ordered to red with M0011 Specifications::Site::Traffic Light Controller::Signal Group
-
state is read with S0001 Specifications::Site::Traffic Light Controller::Signal Group
-
red/green predictions is read with S0025 Specifications::Site::Traffic Light Controller::Signal Group
-
series can be started/stopped with M0012 Specifications::Site::Traffic Light Controller::Signal Group
-
list size is read with S0017 Specifications::Site::Traffic Light Controller::Signal Group
-
follow startup sequence after yellow flash Specifications::Site::Traffic Light Controller::Signal Group
-
list size is read with S0016 Specifications::Site::Traffic Light Controller::Detector Logic
-
status is read with S0002 Specifications::Site::Traffic Light Controller::Detector Logic
-
forcing is read with S0021 Specifications::Site::Traffic Light Controller::Detector Logic
-
forcing is set with M0008 Specifications::Site::Traffic Light Controller::Detector Logic
-
sensitivity is read with S0031 Specifications::Site::Traffic Light Controller::Detector Logic
-
can be requested with M0022 Specifications::Site::Traffic Light Controller::Signal Priority
-
status can be fetched with S0033 Specifications::Site::Traffic Light Controller::Signal Priority
-
status can be subscribed to with S0033 Specifications::Site::Traffic Light Controller::Signal Priority
-
becomes completed when cancelled Specifications::Site::Traffic Light Controller::Signal Priority
-
becomes stale if not cancelled Specifications::Site::Traffic Light Controller::Signal Priority
-
emergency route is read with S0006 Specifications::Site::Traffic Light Controller::Emergency Route
-
emergency route is read with S0035 Specifications::Site::Traffic Light Controller::Emergency Route
-
can be activated with M0005 and read with S0006 Specifications::Site::Traffic Light Controller::Emergency Route
-
emergency routes can be activated with M0005 and read with S0035 Specifications::Site::Traffic Light Controller::Emergency Route
-
can be requested Specifications::Site::Core::Aggregated Status
-
uses null for functional position/state Specifications::Site::Core::Aggregated Status
-
is read with S0015 Specifications::Site::Traffic Light Controller::Traffic Situation
-
is set with M0003 Specifications::Site::Traffic Light Controller::Traffic Situation
-
list size is read with S0019 Specifications::Site::Traffic Light Controller::Traffic Situation
-
exchanges correct connection sequence of rsmp version 3.1.1 Specifications::Supervisor::Connection Sequence
-
exchanges correct connection sequence of rsmp version 3.1.2 Specifications::Supervisor::Connection Sequence
-
exchanges correct connection sequence of rsmp version 3.1.3 Specifications::Supervisor::Connection Sequence
-
exchanges correct connection sequence of rsmp version 3.1.4 Specifications::Supervisor::Connection Sequence
-
exchanges correct connection sequence of rsmp version 3.1.5 Specifications::Supervisor::Connection Sequence
-
exchanges correct connection sequence of rsmp version 3.2 Specifications::Supervisor::Connection Sequence
-
exchanges correct connection sequence of rsmp version 3.2.1 Specifications::Supervisor::Connection Sequence
-
exchanges correct connection sequence of rsmp version 3.2.2 Specifications::Supervisor::Connection Sequence
-
receives aggregated status Specifications::Supervisor::Aggregated Status